Red Tag / Green Tag

Red Tag

Installer
I added a receptacle outlet to a bedroom circuit in a house that was 20 years old. The receptacle is not AFCI protected. The installation was red tagged.

Why?


Top 3 Changes to the 2011 NEC

1. 210.20(I). Foyers.

Foyers that are not part of a hallway in accordance with 250.52(H) and that have an area that is greater than 60 sq. ft. shall have a receptacle(s) located in each wall space 3 ft. or more in width and unbroken by doorways, floor-to-ceiling windows and similar openings.


Question: Where are the receptacle outlets required in the foyer in these drawings? Click on the image below to find out.


Question of the Season

Which of the following locations for a GFCI receptacle is a violation of the NEC?

a. On a kitchen countertop.

b. Outdoors, mounted 30 inches above grade.

c. Installed on a garage ceiling and used for the garage door opener in a dwelling unit.

d. Next to a bathroom sink.

Know the answer? Email us at: newsletter@jadelearning.com. The first two people to respond with the correct answer and their name and mailing address will receive a prize from JADE Learning.


© 2011 JADE Learning

Phone: 1-800-443-5233 - Web site: www.JadeLearning.com

Washington Licensees

2011 NEC Adoption and Technical Advisory Committee Suspended


The Governor's Executive Order 10-06 limits the department to implementing rules required by the 2010 legislative session. The adoption of the 2011 NEC, current revision proposals collected during 2010, and the Technical Advisory Committee have all been suspended.


Rule development activity cannot resume until January 1, 2012, and usually takes 9-10 months to complete.

New fees were effective October 1, 2010 and are available on L&I's web site.
Click here to view JADE Learning's currently approved courses.

Click here to check your continuing education hours.

 

 


More I Fixed It!

There I Fixed It

View More...

You Tube Video

An Adventure in the Sky. Click here to see video of a worker climbing a 1,768 foot Guided Tower.